Model 2DPC1.7-45-24-300

The 2DPC1.7-45-24-300 is a 300W brushless DC solar submersible pump with a plastic impeller. Its 2 inch series format is a candidate for narrow clean-water wells, household storage tanks and modest garden water demand. Selection depends on the actual flow required at the total dynamic head, not motor power alone.

المواصفات

طراز الشركة المصنعة 2DPC1.7-45-24-300
Catalogue pump power 300 W
الجهد الاسمي للمحرك 24 V
Catalogue optimum DC input 30 إلى 48 V تيار مستمر
أقصى تدفق عند نهاية المنحنى 1.7 m3/h
أقصى ارتفاع ضخ عند نهاية المنحنى 45 m
فتحة خروج المضخة 0.75 بوصة
مقاس المضخة سلسلة 2 بوصة
البنية Brushless DC motor with plastic impeller
Catalogue lead cable 2 m
Catalogue PV open circuit voltage limit Below 60 V

Maximum flow and maximum head are separate curve endpoints, not a simultaneous operating point. Actual output depends on duty head, solar input, controller matching and site conditions.

A compact option for narrow well water supply

Start with the measured internal diameter of the well casing. The 2 inch series name is not a guarantee that the complete pump, cable, joints and outlet assembly fit every 2 inch casing. Confirm installation clearance and the offered pump dimensions before ordering.

The catalogue lists a 45 m maximum head and a 1.7 m3/h maximum flow. These are different endpoints of the pump curve. If the dynamic water level, tank elevation and friction losses approach 45 m, useful delivery will be much lower than the maximum-flow figure.

This 300W model has a higher catalogue head endpoint than the existing 200W 2DPC model. That does not make it the better choice for every well. Compare the required operating point, the well recovery rate and available solar input.

Supplier performance curves

Supplier 2DPC series head and flow curves including model 2DPC1.7-45-24-300
Original supplier series curves. Follow the line labelled 2DPC1.7-45-24-300. The axes show flow in m3/h and total head in metres. Request the current curve for the offered pump before ordering.

Solar panels and controller matching

The supplied catalogue lists 30 to 48 V DC as the optimum DC input and below 60 v as the PV open circuit voltage limit. These catalogue values must be confirmed against the actual controller supplied. Nominal motor voltage, PV operating voltage and PV open circuit voltage are different specifications.

The supplier lists PV nameplate power of at least 1.3 times pump power as a preliminary reference. This is not a complete array design or a daily water output guarantee. Check local irradiation, seasonal demand, cold-weather open circuit voltage, hot-weather operating voltage and the controller current limit before selecting modules.

A qualified installer should specify cable length and conductor size, waterproof connections, dry-run protection, tank level controls and the required electrical protection. A DC listing does not establish AC or generator compatibility.

الأسئلة الشائعة

Will this pump deliver 1.7 m3 per hour at 45 m

No. The flow and head values are separate maximum endpoints. A quotation should identify the required flow at the calculated total dynamic head and check that point against the current model curve.

Does the 24V rating mean any 24V solar panel will work

No. The nominal motor rating is distinct from the catalogue optimum DC input of 30 to 48 V and the PV open circuit voltage limit below 60 V. The actual panel string and external controller must be checked together, including temperature effects and current limits.

Can it fill a tank without a battery

A correctly specified solar pumping controller and PV array can support daytime tank filling without battery storage. Water available after sunset depends on the usable water already stored or on a separately specified backup system.

Is this a complete ready to install kit

The photograph is a supplier series reference, not a packing list. Confirm the pump, controller, sensors, cable extensions, fittings and solar panels in the quotation. The catalogue lists a 2 m lead cable, which is not the complete cable length for a deep installation.

Supply and documentation

Suntrica is a trading company sourcing this model from its pump supplier DIFFUL. We coordinate model selection, system component matching and export quotations. We do not present the supplier factory or its test results as our own.

Specification reference: supplied neutral solar pump catalogue, printed page 02, checked against the August 2025 supplier specification sheet. The photograph is the supplier reference for this series. Request the current model curve, controller manual, destination-specific compliance documents, warranty terms and packing list with the quotation. No current price, stock level or delivery time is implied.