{"id":90909,"date":"2026-11-02T07:43:37","date_gmt":"2026-11-01T23:43:37","guid":{"rendered":"https:\/\/www.solar-machinery.com\/how-to-order-custom-small-solar-panels.html"},"modified":"2026-11-09T02:08:43","modified_gmt":"2026-11-08T18:08:43","slug":"how-to-order-custom-small-solar-panels","status":"publish","type":"post","link":"https:\/\/www.solar-machinery.com\/ru\/how-to-order-custom-small-solar-panels.html","title":{"rendered":"How to Order Custom Small Solar Panels: From Drawing to Installation"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><p>Standard solar modules are convenient when the available space and electrical design are flexible. They are less useful when a product enclosure, lighting pole, monitoring station, portable system or small pumping controller has a fixed footprint. In these projects, a custom small solar panel can solve the mechanical problem\u2014but only if the electrical and production details are defined before manufacturing begins.<\/p>\n<p>A reliable order starts with a drawing and an electrical target, then moves through sample approval, batch control, packaging and installation. The following checklist explains what buyers should confirm at each stage.<\/p>\n<h2>1. Define the application before choosing panel dimensions<\/h2>\n<p>Panel length and width should not be the first decision. Begin with the load, operating hours, battery voltage, controller type, installation location and worst-season sunlight. These inputs determine the daily energy requirement and the minimum charging power. The available mounting area then sets the practical limit for the module.<\/p>\n<p>For battery charging, \u201c12V panel\u201d is only a market description. The actual module must have a suitable operating voltage (Vmp) and open-circuit voltage (Voc) for the charge controller and battery architecture. A panel that physically fits can still be electrically unsuitable.<\/p>\n<figure style=\"margin:24px auto;text-align:center;\"><img decoding=\"async\" src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/compact-solar-panel-front-view.jpg\" alt=\"Compact framed solar panel with a custom cell layout\" style=\"width:800px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"eager\"><figcaption>A compact framed module may use a cell layout selected for the required voltage, current and available surface area.<\/figcaption><\/figure>\n<h2>2. Put the electrical requirements on the specification sheet<\/h2>\n<p>At minimum, a custom-module request should state:<\/p>\n<ul>\n<li>Required rated power under standard test conditions<\/li>\n<li>Target Vmp, Voc, Imp and Isc<\/li>\n<li>System and battery voltage<\/li>\n<li>Charge-controller or MPPT input limits<\/li>\n<li>Cable length, conductor size, connector type and polarity<\/li>\n<li>Expected operating temperature and installation environment<\/li>\n<\/ul>\n<p>Do not accept a quotation based on wattage alone. Two panels with the same rated power can have different voltages and currents because of their cell count and interconnection pattern. The supplier should confirm the finished module data, not only the nominal cell rating.<\/p>\n<h2>3. Freeze the mechanical drawing before sample production<\/h2>\n<p>The drawing should show the overall length, width and thickness; frame profile; mounting-hole positions; junction-box or cable-exit location; connector orientation; and allowable dimensional tolerances. If the panel fits into an enclosure or metal frame, leave realistic clearance for production tolerance, thermal movement and installation access.<\/p>\n<p>Edge finish matters on small modules that are frequently handled. Frames and corners should be smooth, fasteners secure and cable exits protected against pulling and abrasion. A neat front surface is useful, but the rear construction, sealing and termination quality deserve the same attention.<\/p>\n<figure style=\"margin:24px auto;text-align:center;\"><img decoding=\"async\" src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/technician-installing-custom-solar-panels.jpg\" alt=\"Technician working beneath a framed solar panel mounting structure\" style=\"width:601px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Mounting dimensions, clamp positions and safe access should be considered before the module drawing is approved.<\/figcaption><\/figure>\n<h2>4. Approve a representative sample\u2014not just a photograph<\/h2>\n<p>A pre-production sample is the best opportunity to find errors before quantity production. Check the physical dimensions against the signed drawing, then verify the frame, glass, cell alignment, cable length, connector and label. Electrical checks should include polarity, Voc, Isc and a power measurement under a controlled test condition.<\/p>\n<p>Where the application requires it, discuss insulation, wet-leakage, pull-force, thermal-cycle or environmental testing with the supplier. A sample that looks correct does not automatically prove long-term outdoor reliability.<\/p>\n<figure style=\"margin:24px auto;text-align:center;\"><img decoding=\"async\" src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/custom-solar-panel-wiring-check.jpg\" alt=\"Technicians checking the rear wiring and junction area of custom solar panels\" style=\"width:800px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Rear-side wiring, cable exit, connector polarity and mechanical protection should be part of sample approval.<\/figcaption><\/figure>\n<h2>5. Lock the bill of materials for batch production<\/h2>\n<p>After the sample is approved, record the materials and construction that made it acceptable. This can include the cell type and grade, glass or front-sheet construction, encapsulant, backsheet, frame profile, junction box, cable and connector. If substitutions are allowed, the approval procedure should be defined in advance.<\/p>\n<p>Batch inspection should compare production units with the approved sample. Useful checks include dimensions, appearance, cell alignment, frame condition, cable and connector details, polarity and electrical output. Sampling frequency should reflect order quantity and project risk.<\/p>\n<figure style=\"margin:24px auto;text-align:center;\"><img decoding=\"async\" src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/custom-small-solar-panel-production-batch.jpg\" alt=\"Batch of small framed solar panels in several custom sizes\" style=\"width:800px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Custom orders may contain several sizes, so model identification and batch segregation are important.<\/figcaption><\/figure>\n<h2>6. Design packaging around the panel size and transport route<\/h2>\n<p>Small modules are easier to handle than full-size modules, but exposed glass, frames and connectors can still be damaged by impact, vibration or excessive strapping pressure. Packaging should prevent panel-to-panel movement and protect corners and faces. Cable ends should be secured so they cannot scratch adjacent surfaces.<\/p>\n<p>For export shipments, confirm pallet dimensions, stack height, gross weight, moisture protection and handling marks. Photos of the finished packing are useful, but the packing method should also be recorded in the quotation or order specification.<\/p>\n<figure style=\"margin:24px auto;text-align:center;\"><img decoding=\"async\" src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/small-solar-panels-packed-on-pallets.jpg\" alt=\"Custom small solar panels protected and strapped on pallets\" style=\"width:623px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Corner protection, separation and controlled strapping help prevent movement and edge damage in transit.<\/figcaption><\/figure>\n<figure style=\"margin:24px auto;text-align:center;\"><img decoding=\"async\" src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/small-solar-panels-ready-for-shipment.jpg\" alt=\"Stacked small solar panels prepared for packing and shipment\" style=\"width:700px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Finished panels should be counted, separated by model and checked before final packing.<\/figcaption><\/figure>\n<h2>7. Installation quality still determines field performance<\/h2>\n<p>Even a correctly manufactured panel can underperform if it is shaded, poorly ventilated or mounted at the wrong angle. Keep the active surface clear of structural shadows, follow the approved clamp or bolt locations, and avoid twisting the frame. Cable routing should include strain relief, weather protection and a path that does not trap water.<\/p>\n<p>Before handover, record the array layout, module quantities, polarity, open-circuit voltage and controller readings. This provides a baseline for later troubleshooting.<\/p>\n<figure style=\"margin:24px auto;text-align:center;\"><img decoding=\"async\" src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/rooftop-custom-solar-panel-array.jpg\" alt=\"Installed custom solar panel array on a rooftop structure\" style=\"width:782px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>An installed array must balance usable roof area, tilt, access, drainage and shading control.<\/figcaption><\/figure>\n<h2>Custom solar panel RFQ checklist<\/h2>\n<table style=\"width:100%;border-collapse:collapse;margin:20px 0;\">\n<thead>\n<tr>\n<th style=\"border:1px solid #ddd;padding:10px;text-align:left;\">Item<\/th>\n<th style=\"border:1px solid #ddd;padding:10px;text-align:left;\">Information to provide<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #ddd;padding:10px;\">\u0417\u0430\u044f\u0432\u043a\u0430<\/td>\n<td style=\"border:1px solid #ddd;padding:10px;\">Load, operating hours, battery and controller<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:10px;\">Electrical<\/td>\n<td style=\"border:1px solid #ddd;padding:10px;\">Power, Vmp, Voc, Imp, Isc and tolerance<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:10px;\">Mechanical<\/td>\n<td style=\"border:1px solid #ddd;padding:10px;\">Drawing, dimensions, thickness, holes and frame<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:10px;\">Connection<\/td>\n<td style=\"border:1px solid #ddd;padding:10px;\">Cable length, connector, polarity and junction position<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:10px;\">Environment<\/td>\n<td style=\"border:1px solid #ddd;padding:10px;\">Temperature, humidity, salt, dust, wind and mechanical load<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:10px;\">Quality plan<\/td>\n<td style=\"border:1px solid #ddd;padding:10px;\">Sample approval, test records and batch inspection<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #ddd;padding:10px;\">Logistics<\/td>\n<td style=\"border:1px solid #ddd;padding:10px;\">Quantity, destination, packing and delivery schedule<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Conclusion<\/h2>\n<p>Custom small solar panels are not simply standard modules cut to a different size. Cell layout, voltage, frame, cable, connector, sealing and mounting must work as one design. A clear specification, physical sample and documented inspection plan reduce the risk of receiving a panel that looks correct but does not fit or charge the system properly.<\/p>\n<p>For a project quotation, send the available panel area, required power, system voltage, battery and controller details, cable and connector requirements, installation environment, quantity and destination. We can help organise the technical specification and compare suitable custom-module options.<\/p>\n<\/p>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":90936,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_seopress_robots_follow":"","_seopress_robots_imageindex":"","_seopress_robots_snippet":"","_seopress_robots_primary_cat":"","_seopress_robots_breadcrumbs":"","_seopress_robots_freeze_modified_date":"","_seopress_robots_custom_modified_date":"","_seopress_robots_canonical":"","_seopress_social_fb_title":"","_seopress_social_fb_desc":"","_seopress_social_fb_img":"","_seopress_social_fb_img_attachment_id":0,"_seopress_social_fb_img_width":0,"_seopress_social_fb_img_height":0,"_seopress_social_twitter_title":"","_seopress_social_twitter_desc":"","_seopress_social_twitter_img":"","_seopress_social_twitter_img_attachment_id":0,"_seopress_social_twitter_img_width":0,"_seopress_social_twitter_img_height":0,"_seopress_redirections_value":"","_seopress_redirections_enabled":"","_seopress_redirections_enabled_regex":"","_seopress_redirections_logged_status":"","_seopress_redirections_param":"","_seopress_redirections_type":0,"_seopress_analysis_target_kw":"","themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false,"footnotes":""},"categories":[2],"tags":[128,129,131,132,130],"class_list":["post-90909","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","tag-custom-small-solar-panels","tag-oem-solar-panel","tag-sample-approval","tag-solar-module-quality","tag-solar-panel-specification"],"metadata":{"themepark_post_bcolor":["#f5f5f5"],"themepark_post_width":["1022px"],"themepark_post_img_po":["left"],"themepark_post_main_p":["100"],"themepark_auto_metas":["a:1:{s:6:\"ector0\";s:10933:\"<p>Standard solar modules are convenient when the available space and electrical design are flexible. They are less useful when a product enclosure, lighting pole, monitoring station, portable system or small pumping controller has a fixed footprint. In these projects, a custom small solar panel can solve the mechanical problem\u2014but only if the electrical and production details are defined before manufacturing begins.<\/p>\r\n<p>A reliable order starts with a drawing and an electrical target, then moves through sample approval, batch control, packaging and installation. The following checklist explains what buyers should confirm at each stage.<\/p>\r\n\r\n<h2>1. Define the application before choosing panel dimensions<\/h2>\r\n<p>Panel length and width should not be the first decision. Begin with the load, operating hours, battery voltage, controller type, installation location and worst-season sunlight. These inputs determine the daily energy requirement and the minimum charging power. The available mounting area then sets the practical limit for the module.<\/p>\r\n<p>For battery charging, \u201c12V panel\u201d is only a market description. The actual module must have a suitable operating voltage (Vmp) and open-circuit voltage (Voc) for the charge controller and battery architecture. A panel that physically fits can still be electrically unsuitable.<\/p>\r\n<figure style=\"margin:24px auto;text-align:center;\"><img src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/compact-solar-panel-front-view.jpg\" alt=\"Compact framed solar panel with a custom cell layout\" style=\"width:800px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"eager\"><figcaption>A compact framed module may use a cell layout selected for the required voltage, current and available surface area.<\/figcaption><\/figure>\r\n\r\n<h2>2. Put the electrical requirements on the specification sheet<\/h2>\r\n<p>At minimum, a custom-module request should state:<\/p>\r\n<ul>\r\n<li>Required rated power under standard test conditions<\/li>\r\n<li>Target Vmp, Voc, Imp and Isc<\/li>\r\n<li>System and battery voltage<\/li>\r\n<li>Charge-controller or MPPT input limits<\/li>\r\n<li>Cable length, conductor size, connector type and polarity<\/li>\r\n<li>Expected operating temperature and installation environment<\/li>\r\n<\/ul>\r\n<p>Do not accept a quotation based on wattage alone. Two panels with the same rated power can have different voltages and currents because of their cell count and interconnection pattern. The supplier should confirm the finished module data, not only the nominal cell rating.<\/p>\r\n\r\n<h2>3. Freeze the mechanical drawing before sample production<\/h2>\r\n<p>The drawing should show the overall length, width and thickness; frame profile; mounting-hole positions; junction-box or cable-exit location; connector orientation; and allowable dimensional tolerances. If the panel fits into an enclosure or metal frame, leave realistic clearance for production tolerance, thermal movement and installation access.<\/p>\r\n<p>Edge finish matters on small modules that are frequently handled. Frames and corners should be smooth, fasteners secure and cable exits protected against pulling and abrasion. A neat front surface is useful, but the rear construction, sealing and termination quality deserve the same attention.<\/p>\r\n<figure style=\"margin:24px auto;text-align:center;\"><img src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/technician-installing-custom-solar-panels.jpg\" alt=\"Technician working beneath a framed solar panel mounting structure\" style=\"width:601px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Mounting dimensions, clamp positions and safe access should be considered before the module drawing is approved.<\/figcaption><\/figure>\r\n\r\n<h2>4. Approve a representative sample\u2014not just a photograph<\/h2>\r\n<p>A pre-production sample is the best opportunity to find errors before quantity production. Check the physical dimensions against the signed drawing, then verify the frame, glass, cell alignment, cable length, connector and label. Electrical checks should include polarity, Voc, Isc and a power measurement under a controlled test condition.<\/p>\r\n<p>Where the application requires it, discuss insulation, wet-leakage, pull-force, thermal-cycle or environmental testing with the supplier. A sample that looks correct does not automatically prove long-term outdoor reliability.<\/p>\r\n<figure style=\"margin:24px auto;text-align:center;\"><img src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/custom-solar-panel-wiring-check.jpg\" alt=\"Technicians checking the rear wiring and junction area of custom solar panels\" style=\"width:800px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Rear-side wiring, cable exit, connector polarity and mechanical protection should be part of sample approval.<\/figcaption><\/figure>\r\n\r\n<h2>5. Lock the bill of materials for batch production<\/h2>\r\n<p>After the sample is approved, record the materials and construction that made it acceptable. This can include the cell type and grade, glass or front-sheet construction, encapsulant, backsheet, frame profile, junction box, cable and connector. If substitutions are allowed, the approval procedure should be defined in advance.<\/p>\r\n<p>Batch inspection should compare production units with the approved sample. Useful checks include dimensions, appearance, cell alignment, frame condition, cable and connector details, polarity and electrical output. Sampling frequency should reflect order quantity and project risk.<\/p>\r\n<figure style=\"margin:24px auto;text-align:center;\"><img src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/custom-small-solar-panel-production-batch.jpg\" alt=\"Batch of small framed solar panels in several custom sizes\" style=\"width:800px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Custom orders may contain several sizes, so model identification and batch segregation are important.<\/figcaption><\/figure>\r\n\r\n<h2>6. Design packaging around the panel size and transport route<\/h2>\r\n<p>Small modules are easier to handle than full-size modules, but exposed glass, frames and connectors can still be damaged by impact, vibration or excessive strapping pressure. Packaging should prevent panel-to-panel movement and protect corners and faces. Cable ends should be secured so they cannot scratch adjacent surfaces.<\/p>\r\n<p>For export shipments, confirm pallet dimensions, stack height, gross weight, moisture protection and handling marks. Photos of the finished packing are useful, but the packing method should also be recorded in the quotation or order specification.<\/p>\r\n<figure style=\"margin:24px auto;text-align:center;\"><img src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/small-solar-panels-packed-on-pallets.jpg\" alt=\"Custom small solar panels protected and strapped on pallets\" style=\"width:623px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Corner protection, separation and controlled strapping help prevent movement and edge damage in transit.<\/figcaption><\/figure>\r\n<figure style=\"margin:24px auto;text-align:center;\"><img src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/small-solar-panels-ready-for-shipment.jpg\" alt=\"Stacked small solar panels prepared for packing and shipment\" style=\"width:700px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>Finished panels should be counted, separated by model and checked before final packing.<\/figcaption><\/figure>\r\n\r\n<h2>7. Installation quality still determines field performance<\/h2>\r\n<p>Even a correctly manufactured panel can underperform if it is shaded, poorly ventilated or mounted at the wrong angle. Keep the active surface clear of structural shadows, follow the approved clamp or bolt locations, and avoid twisting the frame. Cable routing should include strain relief, weather protection and a path that does not trap water.<\/p>\r\n<p>Before handover, record the array layout, module quantities, polarity, open-circuit voltage and controller readings. This provides a baseline for later troubleshooting.<\/p>\r\n<figure style=\"margin:24px auto;text-align:center;\"><img src=\"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/rooftop-custom-solar-panel-array.jpg\" alt=\"Installed custom solar panel array on a rooftop structure\" style=\"width:782px;max-width:100%;height:auto;display:block;margin:0 auto;\" loading=\"lazy\"><figcaption>An installed array must balance usable roof area, tilt, access, drainage and shading control.<\/figcaption><\/figure>\r\n\r\n<h2>Custom solar panel RFQ checklist<\/h2>\r\n<table style=\"width:100%;border-collapse:collapse;margin:20px 0;\">\r\n<thead><tr><th style=\"border:1px solid #ddd;padding:10px;text-align:left;\">Item<\/th><th style=\"border:1px solid #ddd;padding:10px;text-align:left;\">Information to provide<\/th><\/tr><\/thead>\r\n<tbody>\r\n<tr><td style=\"border:1px solid #ddd;padding:10px;\">Application<\/td><td style=\"border:1px solid #ddd;padding:10px;\">Load, operating hours, battery and controller<\/td><\/tr>\r\n<tr><td style=\"border:1px solid #ddd;padding:10px;\">Electrical<\/td><td style=\"border:1px solid #ddd;padding:10px;\">Power, Vmp, Voc, Imp, Isc and tolerance<\/td><\/tr>\r\n<tr><td style=\"border:1px solid #ddd;padding:10px;\">Mechanical<\/td><td style=\"border:1px solid #ddd;padding:10px;\">Drawing, dimensions, thickness, holes and frame<\/td><\/tr>\r\n<tr><td style=\"border:1px solid #ddd;padding:10px;\">Connection<\/td><td style=\"border:1px solid #ddd;padding:10px;\">Cable length, connector, polarity and junction position<\/td><\/tr>\r\n<tr><td style=\"border:1px solid #ddd;padding:10px;\">Environment<\/td><td style=\"border:1px solid #ddd;padding:10px;\">Temperature, humidity, salt, dust, wind and mechanical load<\/td><\/tr>\r\n<tr><td style=\"border:1px solid #ddd;padding:10px;\">Quality plan<\/td><td style=\"border:1px solid #ddd;padding:10px;\">Sample approval, test records and batch inspection<\/td><\/tr>\r\n<tr><td style=\"border:1px solid #ddd;padding:10px;\">Logistics<\/td><td style=\"border:1px solid #ddd;padding:10px;\">Quantity, destination, packing and delivery schedule<\/td><\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n<h2>Conclusion<\/h2>\r\n<p>Custom small solar panels are not simply standard modules cut to a different size. Cell layout, voltage, frame, cable, connector, sealing and mounting must work as one design. A clear specification, physical sample and documented inspection plan reduce the risk of receiving a panel that looks correct but does not fit or charge the system properly.<\/p>\r\n<p>For a project quotation, send the available panel area, required power, system voltage, battery and controller details, cable and connector requirements, installation environment, quantity and destination. We can help organise the technical specification and compare suitable custom-module options.<\/p>\";}"],"themepark_seo_title":["How to Order Custom Small Solar Panels | Suntrica"],"themepark_seo_description":["Learn how to specify custom small solar panels by size, voltage, wattage, frame, cable and connector, then verify samples, packaging and installation."],"themepark_seo_keyword":["custom small solar panels, OEM solar panel, solar panel specification, sample approval, solar module quality"],"_thumbnail_id":["90936"],"_autoid":["1"],"_blocktemname":["\u65b0\u95fb\u8be6\u60c5\u6a21\u677f"],"_edit_lock":["1794161329:1"],"_edit_last":["1"],"catce":["sidebar-widgets4"]},"medium_url":"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/suntrica-news-90909-800x600-1-300x225.jpg","thumbnail_url":"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/suntrica-news-90909-800x600-1-150x150.jpg","full_url":"https:\/\/www.solar-machinery.com\/wp-content\/uploads\/2026\/11\/suntrica-news-90909-800x600-1.jpg","_links":{"self":[{"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/posts\/90909","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/comments?post=90909"}],"version-history":[{"count":1,"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/posts\/90909\/revisions"}],"predecessor-version":[{"id":90953,"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/posts\/90909\/revisions\/90953"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/media\/90936"}],"wp:attachment":[{"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/media?parent=90909"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/categories?post=90909"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solar-machinery.com\/ru\/wp-json\/wp\/v2\/tags?post=90909"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}